MRS600 HE High Efficiency Reverse Osmosis (RO) System featuring dual headed pump and integrated 6.0 gallon (22.7 litre) tank. The tailored blending process removes just the right amount of dissolved solids from the incoming tap water to achieve the desired final water quality.

With the average recovery of 78%, the MRS-600HE system only disposes approximately 1/4 cup of water for each cup of water dispensed. High recovery reverse osmosis technology yields significant savings in water and sewer charges with a minimal environmental footprint.

Requires less than 50% of the electrical energy typically consumed by conventional reverse osmosis systems. On board storage tank provides ample reserve capacity for most applications. For increased reserve capacity, Pentair offers a complete line of storage tanks.

Reduces limescale buildup that can cause excessive machine downtime and increased maintenance costs. Reduces chlorine taste and odor and other contaminants that can adversely affect the taste of water and beverages

Replacement Cartridges:
  • EV962714 2SRBW
  • EV962723 MR600
  • EV962715 GS215ROH
    Spec sheets:
    • Daily Production Rate: 600 gpd (2,271 Lpd) nominal (plus tap water addition for processor with blend) Total daily production rate will vary based on tap water TDS, RO percent rejection and desired blend water TDS. Contact Everpure for assistance estimating this total.
    • Service Flow Rate: Dependant on water pressure in storage tank and line size(s) to equipment.
    • Operating Pressure Requirements: 25 – 80 psi (1.72 – 5.52 bar), non-shock Pressure below 50 psi (3.45 bar) may affect blend system performance.
    • Minimum Static Pressure Requirements: 100 psi (6.89 bar), non-shock
    • Minimum Water Supply: 1.5 gpm (5.7 Lpm)
    • Temperature: 40 – 100°F (4.4 – 38°C)
    • Overall Dimensions: 32″ H x 23″ W x 13.6″ D (81.3 x 58.4 x 34.5 cm) Add 3″ (7.6 cm) on all 4 sides for cover removal and service access.
    • Inlet/Outlet/Wastewater Line Connection: 3/8″ OD tube connection
    • Inlet TDS: 1,000 ppm max. recommended
    • Available Voltages & Power Cord Types: EV9970-38: 115 VAC/60 Hz NEMA 5-15P Plug EV9970-44: 220 VAC/ 50 Hz GB 2099 Plug EV9970-47: 230 VAC/50 Hz Schuko CEE 7/7 Plug EV9970-50: 240 VAC/50 Hz AS 3112 Plug
    • Shipping Weight: 85 lbs (38.6 kgs)